All enquiries by email to: [email protected]

or call our UK phone +44 (0) 113 403 2015 (voicemail out of hours)

Trane Controls Jobs

Install multiple drivers to inter-connect different systems. Future-proof sites by connecting legacy installed systems (e.g. ModBus, Trane Comm3, Trend IQ2) to newer networks (e.g. KNX) as well as new Niagara features. One JACE (or equivalent) controller can have multiple drivers installed to interconnect several systems. To upgrade, we replace the Trane drivers (or controllers) with equipment drivers that communicate with an open BAS front end, such as the industry-leading Tridium or J2 Innovations. Installing Tridium’s JACE controller in place of Trane’s Comm3 or Comm4 devices gives a facility manager the option to integrate legacy Trane equipment with a. Trane® AdaptiView chiller control lets building operating staff take command of the chiller plant in a way never before possible. Optimal chiller operation delivers more hours at peak efficiency, particularly in variable-primary flow applications. Adeo Control Server Gateway DALI & DMX Driver Suite. Adeo Group S.r.l. Central Geothermal System Design and Control. APP-CMC039-EN Quiz; Course Completed; Chilled-Water System Decisions. Chilled-Water System Design Trends. Chilled-Water Terminal Systems. Coil Selection and Optimization. Controls Communication Technology. Cooling Towers and Condenser-Water System Design and Operation. Dedicated Outdoor Air Equipment.

Trane Hvac Controller

All drivers now available for Niagara4.9 release

The Tridium, NiagaraAX & Niagara4 logos are property of Tridium.

Connect to:

Allen Bradley, ASI Controllers, Barber Colman, Clipsal (Schneider), CSI/TAC Inet, EasyIO, Honeywell, Innotech, Johnson, Niagara R2, Novar, OPC Server, Robertshaw, Siemens, Sierra, SMS Multigroup, Staefa, TAP Pager, Trane, Trend
Enquiry form – for further information and pricing

These software drivers install in the same way that any other driver installs on the Niagara system, for example the drivers for BACnet, KNX, Modbus, etc.
By using the software driver, the Niagara controller then appears to the existing network to be a branded controller and able to communicate natively with the network devices.
The installed network can be connected to the Niagara system using the existing wiring and connected devices, sensors and systems. An existing installed network can be fully integrated with new networks, energy management interfaces, mobile interfaces, and all the other tools and facilities of Niagara.
The drivers are written in Java and are fully scalable to tens of thousands of points at high data rates.
The drivers work with all Niagara hardware and software controllers – JACE, Soft JACE, Web Supervisor and the equivalents from OEM suppliers like Honeywell, Distech, etc, also Alerton controllers running Niagara4.

Enquiry form – for further information and pricingStandard use of drivers:Replace branded controller with Niagara controller + MaxLine driver, leaving existing wiring and connected equipment in place.Advantages:Controls
  • add graphics, internet access, analytics, connectivity, remote access and other Niagara advanced features
  • install multiple drivers to inter-connect different systems. Future-proof sites by connecting legacy installed systems (e.g. ModBus, Trane Comm3, Trend IQ2) to newer networks (e.g. KNX) as well as new Niagara features. One JACE (or equivalent) controller can have multiple drivers installed to interconnect several systems.
Trane controls drivers
Recent drivers:-
NotifierOmron FinsOTIS lift
Telegram AppsTekAir
Drivers for Niagara4 and NiagaraAX:-
Allen Bradley CIP and CSP V4InnotechSierra Raven
ASI ControllersJohnson Controls N2 and N2 slave (JACE as VND)SMS Multigroup/Multiuser
Barber Colman ASD & GCMNiagara R2 Staefa Smart2
Clipsal (Schnieder)NovarTAP Pager
CSI/TAC InetOPC ServerTrane Comm3 & Comm4
EasyIO SedonaRobertshaw DMS and MicrosmartTrend IQ2, IQ3, IQ4
Honeywell CbusSiemens System 600

Niagara N4 Driver

Niagara AX/N4 driver, allow customers to have a level of flexibility to choosing controller from different manufacturers, but to be truly open and you need to be able to select among devices supporting any protocol. Using the capabilities along with Niagara's toolsets and drivers. give you the ability to truly select best of breed solutions for your needs. Many times a custome needs to integrate a legacy control system into the Open System. These legacy systems often do not support the newer protocols such a Open System. This requires developer to write a driver to communicate with each system.

Availabled Driver.

  • Allen Bradley Cspv4 TCP driver.
  • Allen Bradley CIP TCP driver.
  • ASI RS485 Serial Driver.
  • Barber-Colman Asd RS485 Serial Driver.
  • Barber-Colman GCM RS232 Serial Driver.
  • Clipsal CGate TCP Client Driver.
  • Clipsal Cbus TCP / Serial Driver.
  • CSI I/Net RS232 Serial Driver.
  • Honeywell Cbus XL TCP Driver. (MIG112 is required).
  • Innotech RS485 Serial Driver.
  • Johnson N2 Open RS485 Serial Driver.
  • Johnson N2 Open Slave TCP Driver (MIG112 is required).
  • Novar RS232 Serial Driver.
  • Omron FINS Ethernet Driver.
  • OPC Server DA 2.0.
  • Robertshaw Microsmart TCP Driver (MIG112 is required).
  • Siemen Apogee DC4 RS485 Serial Driver (Legacy).
  • Siemen Apogee P1 RS485 Serial Driver.
  • SMS TCP/RS232 Serial Driver.
  • Staefa Smart II RS485 Serial Driver (TTL device is required).
  • TAP (Telacator AlphaNumeric Protocol) TCP/RS232 Serial Driver (MIG112 is required when use TCP)
  • TCom Sedona Driver.
  • TComAX R2 TCP Driver.
  • Trane CommThree None Isolated RS485 Serial Driver.
  • Trane CommFour None Isolated RS485 Serial Driver.
  • Trend IQ2 RS232 Serial Driver.
  • Trend TCP Driver.
  • Telegram Alarm Messaging.

Statistics

Members
Members:1
Online
Active Users:1876
Bots:1703
Visits last 24h (live):51
Visits last 24h (bots):43

Trane Controls Software

Driver

Trane Commercial Hvac Controls

Announcements